Product Application

This instrument is suitable for the determination of water vapor transmission of plastic film, aluminum foil plastic film, waterproof material, metal foil and other high barrier materials. The bottle, bag and other containers are also measurable.

                                                    

Standards

This test instrument conforms to the following standards:

ISO 15106-3GB/T 21529DIN 53122-2YBB 00092003.

                                                    

Principle

Using the principle of electrolytic detection sensor method, nitrogen gas with a certain relative humidity flows on one side of the material after humidification, and dry nitrogen flows on the other side of the material with a certain flow. Due to the difference of humidity gradient, water vapor will spread from the high wet side through the membrane to the low wet side. On the low wet side, the water vapor through the sample is carried to the sensor by the flow of dry nitrogen, the electrolytic sensor will produce equal proportion of electrical signals for the water molecule electrolysis of the sample. Through the analysis and calculation of the electrical signals of the sensor, the water vapor transmission rate of the sample and other parameters can be calculated accurately.

 

Product Feature

Ÿ   Imported micro moisture electrolysis sensor, flow controller, valve, pipe connectors.

Ÿ   Patented pipe flushing technology speeds up testing and makes testing more efficient.

Ÿ   Professional piping system to ensure the cleanliness of carrier gas.

Ÿ   PA level micro current measurement technology, advanced precision measurement.

Ÿ   No mechanical knob gas flow adjustment, sample gas and carrier gas flow are fully automated, and operation is more convenient and quick.

Ÿ   Unique installation technology of anti-side leakage seal of sample to enhance sample seal.

Ÿ   Patented fogless humidifier, fully automatic precision control of humidity on the high wet side.

Ÿ   The temperature control technology of pure semiconductor can be heated or cooled at will, with high control accuracy and stable and reliable system.

Ÿ   Whole-process monitoring, automatic recording, adjustable sampling rate, automatic repeat testing, automatic power cut save function.

Ÿ   The test process can be fully monitored. Powerful graph curve function, easy to compare test and analysis.

Ÿ   Automatic test: set test parameters, and the test will be conducted automatically after the test is started, and the test results will be automatically judged and saved.

Ÿ   Host software has encrypted database system, data can be exported, data storage, inquiry, printing, and other functions. Through the analysis of historical data, it is easy to grasp the historical trend of the product.

Ÿ   High efficiency test, low nitrogen consumption, can be tested and verified by national first-level standards.

Ÿ   The system is capable of self-test to avoid continuous testing under fault conditions.

Ÿ   Gas flow monitoring, automatic alarm when there is little or no gas.

Ÿ   The computer software fully complies with the requirements of GMP computerized system, and has the functions of user management, permission management, data audit and tracking.

Technical Specifications

 

Name

W-E-31M

W-E-71M

W-E-41D

W-E-41P

W-E-41X

Test Model

The data is independent

Measurement Range(film) g/m2。24h

0.005~300

(0.01~1000) optional

0.001~40

0.0001~25

0.00005~5

Transmission Area (cm2)

7

50

Sensor Accuracy

0.1ppmv

0.01ppmv

2ppbv

Sample Thickness

<3 mm (Additional attachments are required for thicker)

Test Range (container) g/pkg.24h

0.0001~0.25 (Optional)

Number of Specimens

3

7

4

Temperature Range

1550

Temperature Accuracy

±0.1

Humidity Range

0% RH35%~95%RH ,100%RH (Full-automatic control)

Humidity Accuracy

±1%RH

Carrier Gas

99.999% High-purity Nitrogen (The air source is provided by the user)

Carrier Gas Flow

0~200 mL/min (Automatic control)

Carrier Gas Pressure

0.2MPa

Port Size

1/8 inch metal tubing

Instrument Dimension

720Lx415Wx400H

800Lx470Wx450H

720Lx415Wx400H

Power Supply

AC 220V 50Hz

Net Weight

71kg

87kg

82kg

82kg

82kg

 

System configuration: host machine (built-in temperature and humidity control, pipe control system, signal sensor acquisition system, etc.), testing computer, professional testing software, water well, sampler, nitrogen bottle precision pressure reducing valve, Dow corning vacuum grease, data line.

Optional parts: container test accessories and container temperature control device.

Note: gas source and distilled water are provided by the customer.

Product Application

This instrument is suitable for the determination of water vapor transmission of plastic film, aluminum foil plastic film, waterproof material, metal foil and other high barrier materials. The bottle, bag and other containers are also measurable.

Standards

This test instrument conforms to the following standards:

ISO 15106-3GB/T 21529DIN 53122-2YBB 00092003.

Product Feature

Ÿ   Imported micro moisture electrolysis sensor, flow controller, valve, pipe connectors.

Ÿ   Patented pipe flushing technology speeds up testing and makes testing more efficient.

Ÿ   Professional piping system to ensure the cleanliness of carrier gas.

Ÿ   PA level micro current measurement technology, advanced precision measurement.

Ÿ   No mechanical knob gas flow adjustment, sample gas and carrier gas flow are fully automated, and operation is more convenient and quick.

Ÿ   Unique installation technology of anti-side leakage seal of sample to enhance sample seal.

Ÿ   Patented fogless humidifier, fully automatic precision control of humidity on the high wet side.

Ÿ   The temperature control technology of pure semiconductor can be heated or cooled at will, with high control accuracy and stable and reliable system.

Ÿ   Whole-process monitoring, automatic recording, adjustable sampling rate, automatic repeat testing, automatic power cut save function.

Ÿ   The test process can be fully monitored. Powerful graph curve function, easy to compare test and analysis.

Ÿ   Automatic test: set test parameters, and the test will be conducted automatically after the test is started, and the test results will be automatically judged and saved.

Ÿ   Host software has encrypted database system, data can be exported, data storage, inquiry, printing, and other functions. Through the analysis of historical data, it is easy to grasp the historical trend of the product.

Ÿ   High efficiency test, low nitrogen consumption, can be tested and verified by national first-level standards.

Ÿ   The system is capable of self-test to avoid continuous testing under fault conditions.

Ÿ   Gas flow monitoring, automatic alarm when there is little or no gas.

Ÿ   The computer software fully complies with the requirements of GMP computerized system, and has the functions of user management, permission management, data audit and tracking.

Technical Specifications

 

Name

W-E-31M

W-E-71M

W-E-41D

W-E-41P

W-E-41X

Test Model

The data is independent

Measurement Range(film) g/m2.24h

0.005~300

(0.01~1000) optional

0.001~40

0.0001~25

0.00005~5

Transmission Area (cm2)

7

50

Sensor Accuracy

0.1ppmv

0.01ppmv

2ppbv

Sample Thickness

<3 mm (Additional attachments are required for thicker)

Test Range (container) g/pkg.24h

0.0001~0.25 (Optional)

Number of Specimens

3

7

4

Temperature Range

1550

Temperature Accuracy

±0.1

Humidity Range

0% RH,35%~95%RH ,100%RH (Full-automatic control)

Humidity Accuracy

±1%RH

Carrier Gas

99.999% High-purity Nitrogen (The air source is provided by the user)

Carrier Gas Flow

0~200 mL/min (Automatic control)

Carrier Gas Pressure

0.2MPa

Port Size

1/8 inch metal tubing

Instrument Dimension

720Lx415Wx400H

800Lx470Wx450H

720Lx415Wx400H

Power Supply

AC 220V 50Hz

Net Weight

71kg

87kg

82kg

82kg

82kg

System configuration: host machine (built-in temperature and humidity control, pipe control system, signal sensor acquisition system, etc.), testing computer, professional testing software, water well, sampler, nitrogen bottle precision pressure reducing valve, Dow corning vacuum grease, data line.

Optional parts: container test accessories and container temperature control device.

Note: gas source and distilled water are provided by the customer.

Product message
 
Content:
* Entered characters:0 Word
Less than or equal500Character
Company name:
*
Please enter your name of the entity
Your name:
*
Less than or equal to 20 characters (including AZ, az ,0-9, Chinese characters, excluding special characters)
Mobile:
*
By digital, "+", in the bars "-" the composition, the maximum allowable 20 characters
Your E-mail:
*
Example:example@mail.com
Verification code:
   
喜盈盈彩票开户 任我赢机器人 吉吉彩票注册开户投注平台 微信pk10机器人漏洞 博冠彩票注册开户投注平台 立鼎彩票注册开户投注平台 旺彩彩票平台 利澳彩票注册开户投注平台 云南11选5分布走势图 乐胜彩票注册开户投注平台